Hmi panel manufacturer and supplier today: Create the external model of the system function design model is mainly to consider the data structure, overall structure and process description of the software, interface design is generally only as an accessory, only the user’s situation (including age, gender, psychological situation, literacy, personality, ethnic background, etc.) have an understanding of the user to design an effective user interface; according to the end user’s hypothesis of the future system (referred to as the system hypothesis) The user model is designed to match the system image (external characteristics of the system) obtained after the system is implemented, so that the user can be satisfied with the system and can use it effectively; the information given by the system hypothesis should be fully considered when building the user model, and the system image must accurately reflect the syntactic and semantic information of the system. In short, only by understanding the user and the task can a good human-machine interface be designed. Read additional information at hmi touch screen.
Reasonable Structural Type: There are two structural types: main module and extended module. The average price of each I/O point of the integral PLC is cheaper than that of the module type, and the volume is relatively small, which is generally used in the small control system with a fixed system process; The function expansion of module plc is flexible and convenient, and there is a large choice in the number of I/O points, the ratio of input points to output points, the type of I/O modules…etc, and the maintenance is convenient, generally in more complex control systems.
Consistency principle: Including the consistency of color, operation area consistency, text consistency. That is, on the one hand, the interface color, shape and font are consistent with national, international or industry common standards. On the other hand, the interface color, shape and font are self-contained, and the color of different devices and their same design state should be consistent. Consistency in the aesthetic design of the interface details makes the operator feel comfortable when looking at the interface, so as not to distract his attention. Consistency also reduces errors for new operators, or for operators dealing with problems in emergency situations.
At the same time, because the electrical room has the characteristics of complex data processing, many inverters, strong voltage interference, and closed space, the requirements for the configuration, stability, and anti-interference of the body are high. The industrial-grade control equipment can be well integrated into the electrical cabinet control equipment, and can effectively control all electrical equipment, in the current era of big data and the Internet of Things, and even directly through remote control equipment, the electrical cabinet equipment monitoring. Read additional information at https://www.mochuan-drives.com/.
Human-machine interface refers to the field of human and machine in information exchange and functional contact or mutual influence or interface said human-machine bonding surface, information exchange, functional contact or mutual influence, refers to the hard contact and soft touch of human and machine, this bonding surface includes not only the direct contact of the point line surface, but also the role of space for information transfer and control at a distance.
Less performance used to match a very high cost, so will it worth? And where is your market point? Maybe more consider another China brand with a very perfect performance too, such as Mochuan brand. Welcome contact us to discuss more. The Second Step: Selecting The HMI Screen Size There are two means of size here. One is screen display screen size, the other is CPU size. Integrating the scale of the entire project, to determine the size of the HMI panel needs, through the project as a whole to present the effect. Do not select the size is too small or too large, becuase too small is look very compact and not enough to operate in well, too large will look the overall proportion of the untuned and waste. It requires engineers to design a good enginnering diagram in advance to allocate the size of each accessory part of the proportion. Wanna win every high value market, it needs to pre-design and seriously selected, but not take for granted.
Typically, a heartbeat detection is used to define the BOOL, the HMI sets this point at a fixed frequency and the PLC resets when it receives a signal that the point is on. If no signal is received for that point to turn on for a period of time, e.g. 5s, the communication is considered broken. The PLC’s memory clock byte is passed to the touch panel interface, which uses a script to assign the value of this byte to an address in another PLC, which then determines whether the two scan cycles of the returned byte are the same. If so, the communication is interrupted.
This type touchscreen panel support 7inch, 9.7inch, 17inch, 22inch and 32inch, is enough to select suitable model for the project from application and cost. There are two operating temperature -10°C to 60°C and -20°C to 70°C. And all the size and model is to support ethernet, 2pcs rs485 or 2pcs rs232 is in optional. Adpoting industrial grade high quality components, high protection level design, comprehensive three-proof coating, no matter the wet underground mine, high temperature gobi or corrosive gas, oil mist or dust factory environment, can easily cope with, easy to handle.
The size range is 4.3inch, 7inch, 9.7inch, 10.1inch, 12inch and 15inch, with ethernet, RS485, RS232 and RS422 to meet different application using. If you have the requirement of HMI, it is good to description of your application and what function wanna realize, then the correct and the most suitable model will be recommended to you. Mochuan Drives offers three series of plc programmable logic controller, there are switch control and motion control with very strong power for choosing. Offering free software, demo, 36months warranty, mature solution. And one-to-one technical supporting online to fast solve the customer technical question. Supporting to take the video to solve the technical question, that is service do you need?
The Fifth Step: Selecting A Supplier The correct undertanding of a supplier is to be able to provide very stable performance products and after sale and technical service, can do online one-to-one timely guidance and solution. In the face of unforeseen events have the feasibility and flexibility of the program to provide. After all, industrial HMI PLC is a technical product, needing for a manufacturer’s cooperation and support, to make customer worry-free. Maybe you can choose Mochuan Drives. A small try will bring a high value, so why not try?