Premium core cutting line supplier factory: Heating of Cables, Motors, and Transformers: Poor power quality can lead to excessive heating in cables, motors, and transformer core cutting machine. This can accelerate the ageing of these components, shorten their lifespan, and potentially lead to catastrophic failures. Maintaining high power quality, including minimizing voltage unbalances, is critical for ensuring the efficient operation of electrical equipment and avoiding the potential negative consequences associated with poor power quality. In conclusion, maintaining high power quality is of paramount importance for the optimal performance and longevity of transformer equipment. High-quality power ensures efficient energy consumption, reduces operational costs, and extends the lifespan of the equipment. It also minimizes the risk of malfunctions, data corruption, and excessive heating of cables, motors, and transformers – issues often associated with poor power quality. Read more details on slitting line machine.
What does the rated value on the nameplate of the transformer mean? The rated value on the transformer nameplate refers to some important electrical parameters and performance indicators of the transformer. Usually includes the following aspects: Rated capacity: The rated capacity of a transformer refers to the maximum load electric power that the transformer can continuously supply. For example, a 10MVA transformer means that the transformer’s maximum load can reach 10 megawatts. Rated voltage: The rated voltage of the transformer refers to the design voltage of the transformer. For example, a 220kV/110kV transformer means that the input voltage of the transformer is 220 kV and the output voltage is 110 kV. Rated frequency: The rated frequency of a transformer refers to the power frequency for which the transformer is designed. In China, the power frequency is usually 50Hz. Short-time withstand current: The short-time withstand current of a transformer refers to the maximum current value that the transformer can withstand in a short period of time. For example, the short-term withstand current of a transformer is 50kA, which means that the transformer can withstand an instantaneous current of up to 50 kA.
Why does the current source inverter need a larger transformer capacity? Current source inverter is a common type of inverter. Its control method adopts current loop control, which has the advantages of high precision and strong adaptability, and is widely used in industrial production. Due to the working characteristics of the current source inverter, a large transformer capacity is required for the following reasons: The current source inverter adopts the intermediate inductance: the current source inverter adopts the intermediate inductor, which can realize the phase difference between the output voltage and the current, so as to realize the frequency conversion control. However, since the intermediate inductor needs to withstand large current and voltage, it is necessary to select a transformer with a larger capacity to ensure the normal operation of the inductor.
CANWIN is not just a length lines company, but also electrical equipment manufacturer. It is the legend of people who have forged their lives with faith and action. CANWIN electrical machinery equipment manufacturing deploys an innovation chain through the industrial chain.Equipment sales can provide integrated solutions; can provide OEM/ODM services to global transformer manufacturers; can provide raw material supply to transformer manufacturers. In the form of cooperation and mutual benefit, set up the transformer manufacturing center and core processing base in the Middle East, India. Dubai. Vietnam. Thailand. etc.
The cut to length line is a special equipment for the production of transformer core, is our latest generation of cross shear line. This cut to length production line is used for shearing, O punching and V notch of transformer core sheet. The special point of this ctl line is that two O punch and one V notch can work at the same time to produce transformer core pieces with 3, 5, 7 steps in vertical direction and 3, 5, 7 steps in horizontal direction.
As one of the best dry type transformer manufacturers & suppliers in China, Canwin specialized in dry type power transformer manufacturing for over 20 years.Our dry transformer is widely used in local lighting, high-rise buildings, airports, terminals CNC mechanical equipment and other places, simply said dry type transformerrefers to the core and winding are not impregnated in the transformer insulation oil.There are two main types of dry type transformers: cast resin dry type transformer (CRT) and vacuum pressure impregnated transformer (VPI).
Power distribution cabinet transformer is one of the important equipment in the power supply and distribution system of industrial and mining enterprises and civil buildings. It lowers the network voltage of 10(6)kV or 35kV to 230/400V bus voltage used by users. This kind of product is suitable for AC 50(60)Hz, three-phase maximum rated capacity 2500kVA(single-phase maximum rated capacity 833kVA, generally not recommended to use single-phase transformer), can be used in the indoor (outdoor), the capacity of 315kVA and below can be installed on the rod, the ambient temperature is not higher than 40℃, not less than -25℃, The maximum daily average temperature is 30℃, the maximum annual average temperature is 20℃, the relative humidity is not more than 90%(the ambient temperature is 25℃), and the altitude is not more than 1000m.
The loss in magnetic flux in the transformer must therefore be minimized by providing a suitable mean between the primary and secondary windings. For this purpose, silicon steel magnetic cores are usually used. By using a core type transformer, magnetic losses are reduced and a greater amount of magnetic flux is conveyed between the primary and secondary coils, thereby increasing the transformer’s overall efficiency. Electrical materials play an important role in the field of engineering technology. Various technologies should be realized through certain equipment, and the equipment needs to be made of specific materials. Without corresponding materials, even technologies and products that are feasible in principle cannot be realized. The emergence of new materials can often bring significant technological progress. Find even more details at https://www.canwindg.com/
Epoxy resin is non – combustible, flame retardant, self – extinguishing solid insulation material, safe and clean. It is also a solid insulation material with proven insulation and heat dissipation technology for more than 40 years.Epoxy resin products can be used for dry type transformer, for insulation parts, for instrument transformer, for electrical composite parts and for room temperature curing. Epoxy resin dry transformer uses epoxy resin as insulation material. The high and low voltage windings are made of copper tape (foil), industrial epoxy resin is poured in vacuum and cured, forming a high strength FRP body structure. Insulation grade F, H. Epoxy resin dry transformer has the characteristics of good electrical performance, strong resistance to lightning impact, strong resistance to short circuit, small size and light weight. Temperature display controller can be installed to display and control the operating temperature of the transformer winding to ensure the normal service life of the transformer.
The main pillar of the smart grid is the smart substation, which is not only an important hub for power transmission and distribution, but also directly affects the operational and monitoring capabilities of the smart grid through its operational safety and stability. Through the network, information can be exchanged, and the transformer can share information with the process layer and the station control layer. On the premise of ensuring product performance, the integration of monitoring, control, measurement, protection, and metering is designed to achieve the integration of transformer components with actuators, sensors, and transformers.
Connection group label: According to the phase relationship between the primary and secondary windings of the transformer, the transformer windings are connected into various combinations, which are called the connection group of the windings. In order to distinguish different connection groups, the clock notation is often used, that is, the phasor of the line voltage on the high-voltage side is used as the long hand of the clock, fixed at 12, and the phasor of the line voltage on the low-voltage side is used as the short hand of the clock. The number of the short hand indicates the connection group label. For example, Dyn11 indicates that the primary winding is (triangle) connected, and the secondary winding is (star) connected with a center point, and the group number is (11) points.